Hi Katrice,
Thanks! But in my case both the radio buttons are selected by default. Kindly help to make anyone selected by default
Thanks,
Jonathan.
Hi Katrice,
Thanks! But in my case both the radio buttons are selected by default. Kindly help to make anyone selected by default
Thanks,
Jonathan.
I tried to change a property like this:
lo_property->set_updatable( abap_true ).
It works. Only annotations are not.
Hi Mohan,
Does the input file has all the data for all the fields, the error is talking about some incomplete data in the file. Can you cross check.
Have a look at RelativeValue functionality. It'll be easier for you to read through the worked example in the help than me to try and fit it to your situation
Hi Smart,
I doubt on this during goods movement.
You need to check the config in two places
1. Serial number profile - Dont assign equipment category
2. Default Equipment - Dont give any default equipment category
When you create using IQ01, you will enter the Equipment Category, but unless you activate the equipment view, equipment will not be created.
Regards
Terence
Hi Pintu,
checked & maintained properly . Still error is there.
if enter the input values
Posting period = 1 giving no result
if enter posting period = 01 giving correct result pls give the solutions how to achieve above task.
Hi,
I am trying to access my graphical calculation view by xsodata service and I am getting this exception.
However I'm able to access all other view (.hdbview).
My SYSTEM user has all privledges of "_SYS_BIC" schema.
Can anyone please tell which additional privilege is required ?
Regards,
Siddharth Vedi
Hello Ahmed,
To update 'normal' balance sheet accounts (BS accounts which are
not reconciliation accounts of the receivables and payables)
in classic PCA you have to maintain them in trx. 3KEH or as well
in trx. 3KEI for relevant controlling area.
Please execute the following:
1/ assign account to a default profit center for controlling
area KSID in trx. 3KEH.
2/ Transfer FI doc. into classic pca additionally
using trx. 1KE8. Please consider the note 858363 for more
information how to use trx. 1KE8.
Best regards,
Jason
what settings should I make?
Sure Matt...
Thank you!
Hi everybody,
I was just struggeling with an error with the Explorer Indexing server which gave me "Maximum character output size limit reached. Contact your BusinessObjects administrator. (Error: ERR_WIS_30272)"
As per thread above I was able to fix the problem by increasing the "Binary Stream Maximum Size (MB)" of the WebiProcessingServer.
In the past my understanding of this parameter was that this is limiting the output file size of character files (i.e. csv or txt) for the user. Now I'm learning that this is applying to internal processes as well.
We have kept this parameter quite low, as we don't want users to be able to export a big amount of data to their local PCs for data security reasons.
Is there any way to limit the output file size for users at another place instead?
Thanks for any good hint.
Best Regards - Johannes
Error Messages:
at com.businessobjects.datadiscovery.search.business.ExplorationIndexesBuilder.loadExplorationSpaceRecords(ExplorationIndexesBuilder.java:280)
|59B3B574D53E4B9382E54548622A3D6C3|2015 08 25 09:26:49.752|+0200| |Error| | | |explorerIndexing_dwhbip.ExplorerIndexingServer_6487|11952| 305|ExecutorWorkerThread| ||||||||||||||||||||com.businessobjects.datadiscovery.search.business.ExplorationIndexesBuilder||Unable to load the exploration space data.
com.businessobjects.datadiscovery.dataproviderapi.DataSourceProviderException: The execution of the specified analysis query failed.
Caused by: com.businessobjects.sdk.core.server.CommunicationException$UnexpectedServerException: Maximum character output size limit reached. Contact your BusinessObjects administrator. (Error: ERR_WIS_30272)
Please maintain 0% in Condition type MWAS in TCODE - FTXP for Tax code -16.
It will update the Table T007a.
Regards,
Sharad Tiwari
Hi Experts,
I search on STMS transaction code, Import History > Display More tab and SE16 transaction code tables. But I could not find anything about terminal / hostname / PC name. Actually I must learn the request transport from which computer?
Thanks
Hi gurus.
I want to create a PCR to compare two wage types in the PIT. I have two existing wage types /141 and /142 in my RT and I want to take values from wage type /141 and add them to wage type /141. The reason being that, you can not have both wage types at the same time.
Thanks..
Regards
Letlapa
Dear expert,
For business requierements we had to create a 2nd DB in our IQ server. We did it through the CREATE DATABASE statement from the Interactive SQL client in the same server.
The DB was properly created and is up and running right now. However, the problem is we cannot see this NEW DB from the SAP IQ Cockpit Agent... We are only able to manage the OLD DB. I understand we should be able to manage both... right?
Any help/input would be really appreciated.
Thank you very much and best regards,
Pau
Better show the code what you tried then you will get correct answer
So I guess that here is the clue - one more question: do you know how to call output determination so I can use it in postprocessing? It would resolve the issue I think.
BR,
Maciej
If you want to skip members containing some list of characters (and this list is containing special characters like "*" and "?") then you have to use routine badi. Javascript in conversion file is only able to change the member id, but not to skip it. You may try to rename all "bad" members to some dummy id...
Vadim